Model |
TOB-CT-4008-5V20A-NTFA |
Input Power |
AC 220V ±10% / 50Hz |
resolution |
AD:16bit;DA:16bit |
Input Resistance |
≥1MΩ |
Input Power |
5671W |
Channel Features |
Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure |
Channel Control Mode |
Independent Control |
Voltage |
Per Channel Voltage Range |
0-5V |
Min discharge Voltage |
0V |
Accuracy |
± 0.1% of FS |
Stability |
± 0.1% of FS |
Current |
Per Channel Current Range |
0.1-20A |
Accuracy |
± 0.1% of FS |
Stability |
± 0.1% of FS |
Power |
Per Channel Output Power |
100W |
Stability |
± 0.2% of FS |
Time |
Current Response Time |
10ms (0-Full Range) |
Step Time Range |
≤(365*24 )hour/step, Time Form Support 00:00:00(h,min:s,ms) |
Accessory channel |
Type |
Temperature |
Temperature range |
-25℃-110℃ |
Accuracy |
±1℃ |
Resolution |
0.1℃ |
Data Recording |
Record Condition |
Minimum Time Interval: 100ms |
Minimum Voltage Interval: 10mV |
Minimum Current Interval : 40mA |
Record Frequency |
10Hz |
Charge |
Charge Mode |
Constant Current Charge,Constant Voltage Charge, Constant Current and Constant Voltage Charge,CPC |
End Condition |
Main Channel : Voltage,Current,Relative Time,Capacity,-ΔV |
Accessory channel : Temperature |
Discharge |
Discharge Mode |
CCD,CPD,CRD |
End Condition |
Main Channel : Voltage,Current,Relative Time,Capacity,-ΔV |
Accessory channel : Temperature |
Pulse |
charge |
CCC |
Discharge |
CCD |
Min Pulse Width |
500ms |
Automated Switch |
Automated switch from charge to discharge for each pulse |
End Condition |
Voltage, Test Time |
DCIR |
Support DCIR testing |
Cycle |
Loop Measure Range |
1~65535 times |
Max Steps Per Loop |
254 |
Nested Loop |
Nested loop Function,Max Support 3 Layers |
Protection |
Software Protection |
l Power-down Data Protection |
l Off-line Testing Function |
l Setting Protection Condition,Setting Parameter: Low Voltage limit,Upper Voltage limit,Low Current limit, Upper Current limit,Delay Time |
1 Setting protection for accessory channel : Temperature limit |
Hardware Protection |
Additional Anti-reverse Protection Model |
Voltage and Current Testing Sample |
4-wire connecting |
Noise |
<85dB |
Database |
MySQL Database |
A Means of Communication of Upper Machine |
TCP/IP Protocol |
Data Output |
EXCEL,TXT |
Communication Interface |
Ethernet Port |
Per Unit Main Channels No. |
8 |
Dimensions (L*W*H) |
12U,about 650*600*850(mm) |