$14~$20
Zemic Load Cells For Sale – Customize H8C C3 Zemic Cell
LP7110H zemic load cell uses Weston bridge principle, alloy steel or stainless steel elastomer, with high precision strain gauge material imported from Europe, using deep hole patch technology, imported glue. High precision and high reliability weighing load cells are manufactured by good process flow and high precision measuring equipment.
Process flow: Patch (pre-cured, post-cured) → Bridge wire → temperature compensation → Initial test → Sealing → Strain-hole laser welding → Initial test → Standardized compensation → Re-test → Sealing (Cleaning glue) → Packing and storage
Quick Details
Place of Origin:
Zhejiang, China
Brand Name:
Locosc
Model Number:
LP7110A
Usage:
PRESSURE SENSOR
Theory:
Resistance Sensor
Output:
Analog SENSOR
Application:
Industrial Automation, platform scale, pallet scale, weighing module.
Output Function:
OverTemp, UnderTemp
D/C:
LP7110A
Item:
sqb shear beam load cell
Excitation:
4~15 VDC, Maximum 15VDC
Sensitivity (Cn): load cell:
2.0 ± 0.002mv/V
Non-linearity: load cell:
± 0.02% F.S.
Creep (30 min): load cell:
± 0.02% F.S.
Input Impedance: load cell:
385 ±10 Ω
Output Impedance: load cell:
351 ± 2 Ω
Safe overload: load cell:
150% F.S.
Destructive Load: load cell:
200% F.S.
Packaging & Delivery
Selling Units:
Single item
Single package size:
29X24X11 cm
Single gross weight:
4.000 kg
Package Type:
Foam into inner box, then into strong export carton,digital load cell
Lead Time :
Quantity(Pieces) | 1 - 4 | >4 |
Est. Time(days) | 7 | To be negotiated |
Specification:
Input Impedance | 385±10Ω |
Output Impedance | 351±2Ω |
Operation Temperature | -10~+40°C |
Safe overload | 150%F.S |
Destructive Load | 200%F.S |
Excitation Recommended | 4~12VDC, Max:15vDC |
Cable | Length: 2.5-5m Exc+( red), Exc-(black),4-wire with shield |
Sig+(green), Sig-(White) | |
Construction | Alloy Steel or Stainless steel, IP67. |
Application for | Floor scales, pallet scales weighing module etc |